Below are some common troubleshooting errors seen on the DPT controller.
ERROR CODE | NAME | POTENTIAL CAUSE(S) | TROUBLESHOOTING |
---|---|---|---|
E01 | Position Lost (The desk has an unknown position and needs to be initialized) | * Position error * New Desk Leg added | * Initialize the system (P1) |
E03 | General Overload Down (Overload in downward direction has occurred) | * Obstruction * Bad leg or motor cable | * Check all cable connections, (P2) initialize the system (P1) * Troubleshoot components by initializing 1 at a time (only possible with Plug & Play configuration) (P4) |
E10 | Power fail (Power fail happened, or power regulator adjusted below 10%) | * Mains cable pulled during driving * Internal fault * Only 1 battery for a 3- or 4-channel system * “E10 is a power fail, voltage on power supply drops below a certain limit, power removed” | * Check mains cable is not caught, and is allowed to freely travel * Use strain-relief loop built into control box * Use a 2nd battery; charge batteries |
E16 | Key error (Illegal keys pressed) | * Hitting multiple buttons simultaneously | * Check desk panel |
E23 | Ch1 missing (Channel 1 is detected missing) | * Disconnection * Faulty motor cable * Faulty motor in leg | * Check Motor cable connections and Integrity (P2) * Change Motor cable or Desk Leg * Initialize the system (P1) |
E41 | Ch1 overload up (Overload up occurred on channel 1) | * Leg is overloaded * Hit obstruction * Reached end stop (before initialization at upper end-stop occurs) | * Remove obstruction (P3) * Remove load * Initialize if necessary (P1) |
E42 | Ch2 overload up (Overload up occurred on channel 2) | * Leg is overloaded * Hit obstruction * Reached end stop (before initialization at upper end-stop occurs) | * Remove obstruction (P3) * Remove load * Initialize if necessary (P1) |
E43 | Ch3 overload up (Overload up occurred on channel 3) | * Leg is overloaded * Hit obstruction * Reached end stop (before initialization at upper end-stop occurs) | * Remove obstruction (P3) * Remove load * Initialize if necessary (P1) |
If you come across any error codes not on the list above call Evosite Control Rooms (713) 365-3900 for additional support Monday – Friday between the hours of 8:00am to 4:00pm Central.